Wednesday, 28 September 2016

Fire safety courses

Fire safety courses:

NSA is a professional educational institute offering courses in the field of Fire and Safety. NSA is a professional educational institute offering courses in the field of Fire and Safety. 

 Diploma Fire and Safety Courses:

National Safety Academy
714, M.T.H.Road, Mannurpet 
Padi, Chennai - 600050
Tamilnadu, India.

Phone : 7550075215 , 7550085215 , 044 -26151377

Email : info@safetyacademy.in



Tuesday, 27 September 2016

Diploma in Fire and Safety Engineering

DIPLOMA IN FIRE AND SAFETY ENGINEERING

COURSE CODE: FSS010
COURSE NAME: DIPLOMA IN FIRE AND SAFETY ENGINEERING
COURSE DURATION: ONE YEAR

S.NoSubject CodeSubject
1FSS010-01COMMUNICATIVE ENGLISH AND COMPUTER FUNDAMENTALS
2FSS010-02ACCIDENT PREVENTION AND RISK MANAGEMENT
3FSS010-03FIRE HYDRAULICS AND FIRE LOSS CONTROL
4FSS007-04SAFETY IN ELECTRICAL SYSTEMS
5FSS010-05SAFETY AND PREVENTION IN CHEMICAL/PETRO CHEMICAL INDUSTRIES
6FSS010-06FIRE PREVENTION & CONTROL
7FSS010-07PRACTICAL - I
8FSS010-08PRACTICAL - II
9FSS010-09PRACTICAL - III
10FSS010-10PRACTICAL - IV
11FSS010-11PRACTICAL - V
12FSS010-12PRACTICAL - VI

  Contact us:

National Safety Academy - Head Office
No. 714, 1st Floor, 
M.T.H Road, Mannurpet, 
Chennai 600 050.

Phone : +91 7667442300
Email : info@safetyacademy.in 
National Safety Academy - Branch Office
239/1 Rohini Flats,
Anna Nagar West Extension,
Chennai - 600 101.

Phone : 7550075215
Email : hr@safetyacademy.in 


Saturday, 23 January 2016

LESSION - 7 FIRE HAZARDS CONTROL

LESSON 7

FIRE HAZARDS CONTROL

BEHAVIOUR OF ALUMINIUM IN FIRE;
BEHAVIOR OF PLASTICS IN FIRE:

TEFLON- 260 DEG C COMPOSTION
NYLON- 220 DEG C MELTS (BURNS WITHOUT SMOKE)
POLYPROPYLENE- 570 DEG C IGNITES ( CO IS INVOLVED)
PVC – 140 DEG C MELTS (IGNITES WITH DIFFICULTY BURNS SLOWLY AND PRODUCES WHITE SMOKE (TOXIC)
NEOPRENE RUBBER- DIFFICULTS TO IGNITE

FUEL AND LIUBRICATING OIL NEAR TO FIRE:
MACHINERY SPACE FIRES:
FIGHITNG MACHINERY SPACE FIRES:
PORTABLE EXTINGUISHERS:
STEAMS DRENCHING:
WATER/AFFF SPRAY:
GASEOUS FIRE FIGHTING:
BILGTE FOAM INLET TUBES:
DIESEL GAS TURBINES FIRES:
KITCHEN FIRES:

KITCHEN FIRE LOCAL ACTIONS:

a)      SWITCH OFF THE EQUIPTMENT LOCALLY SWITCHOFF POWER ATR MASTER BREAKER LOCATED OUTSIDED NEAR TO THE ENTRANCE DOOR
b)      SHUT THE FIRE BAFFLE LOCALLY
c)       IF THE FIRE IS IN DEEP FAT FRYERS SHUT THE LID IF POSSIBLE
d)      ATTACK THE FIRE WITH A 9 LITERS FOAM TYPE AFFF EXTINGUISERS
e)      SHUT THE COMMON EXHAUST TRUNKING
f)       SHUT THE LPG GAS VALUE NEAR GAS ROOM
g)      GAS CYLINDERS:
h)      OXYGEN ENRICHMENTS:
i)        ELECTRICAL FIRES;
j)        ELECTRICAL EQUIPTMENTS AT NORMAL VOLTAGE:
k)      FIRE EOUIPTMENTS:
l)        GENERAL FIRES:
m)    EXPLOSIVES AND PYROTECHINICS:
n)      PHOSPOROUS FIRE:
o)      URANIUM FIRE:

AIRCRAFT FIRES:

a)      COMBUSTIBLE MATERAIL CAN BE  IGNITED  BY SPARKING FROM METALLIC OBJECTS EXCITED BY RADIO FREQUENCY RADIATION
b)      PERMANENT DAMAGE CAN BE CAUSED BY INDUCES CURRENTS IN CERTAIN ELECTRONIC EQUIPTMENT PARTICULKARLY THIOSE WHERE SEMI CONDUCTORS ARE INCLUDED
c)       RADIATION FROM THE ARIAL OF HIGH POWER COMMUNICATION AND RADAR TRANSMITTER IS CAPABLE OF CAUSING HAZARDOUS SITUATION SOME OF WHICH INCLUDE FIRE UNLESS APPROPRIATE PRECAUTIONS ARE ALWAYS OBSERVED
d)      EXPLOSIVES MATERIALS AND PROPELLANT  CAN BE IGNITED OR DETONATED BY EITHER THE SPARKING BETWEEN METALLIC CONTACTS OR BY THE INDUCTION OF CURRENTS INTO THE FIRING CURCUITS OF ELECTRICALLY INITIATED EXPLOSIVES DEVICES
      e) WIRELESS COMMUNICATIONS EQUIPTMENTS AND MOBILES PHONES WIILL   
          IGNITES FUEL VAPUORS IN FUEL STATIONS
          IF THE PRESENCE OF FREE FUEL OR FUEL VAPOUR IS EVIDENT OR SUSPECTED, 
          THEN THE FOLLOWING MEASURES ARE TO BE TAKEN ENSURES SAFETY AS                   APPROPRATE

COURSES:

Ø  Diploma in occupational Health And Safety
Ø  Diploma in industrial safety
Ø  Diploma in electrical safety
Ø  Diploma in fire fighting
Ø  Diploma in construction safety
Ø  Certificate in fire and safety engineering
Ø  Diploma in fire and safety engineering
Ø  PG diploma in fire and safety engineering
Ø  Certificate in oil  and Gas safety
Ø  Diploma in oil and Gas safety
Ø  Diploma in health ,safety and Environment
Ø  PG diploma in Health ,safety Environment

JOB PLACEMENT

NSA will give100% job placement assistance to all successful candidates. Some of the Industries are listed below.

   Oil Refineries, 
   Port trust,
   Airport,
   Chemical Industries,
   Insurance,
   Construction and
   service industries are main job providers.

Students passed out from this institute can find job opportunities as Safety Supervisor, Safety Inspector, Safety Officer, Safety Manager, Fireman and Fire Officer.

Contact us:

No. 714, 1st Floor, M.T.H Road,
Mannurpet, Chennai – 600 050.
+91 7667442300
Ph: 26242038 ,26242318
Mobile No:8643055672
Website – http://safetyacademy.in/

Email : info@safetyacademy.in


Sunday, 3 January 2016

Fire Hydraulics and Fire Loss Control

Fire Hydraulics and Fire Loss Control

Lesson 5
Control of Air Flow

ventilation control

flow of air will help the fire. to achive the aim of reducing the flow of air to a room and limit the spread of smoke, in the shortest possible time, the standard procedure is
crash stopping all ventilation fans (blowers / exhausts) as soon as the alarm is raised this action significantly contributes towards reducing the supply of air to the fire prevents the smoke from spreading

a)      restoring power to all ventilation systems so that they may be restarted
b)      supply ventilation is essential system and rooms not affected by fire
      c) contain the smoke within the desireed boundary and prevent the supply of air to the fire
      d) remove smoke from arteas adjacent top the fire and remove all smoke and furnes after       extinction

crash stopping ventilation:

a)      shut down main power supply immediatedly to whole areas of industry. switch on necessary lioghting power supply at the switch board after five seconds.
b)      trip the local starters of general ventilations fans which are not controlled from ventrilation breakers
c)       if industry is provided  with centralized air conditioned air supply it has be controlled at ventilstion trunking
d)      electrical sipplies must be available to all ventilation systems as soon as possible after crash stopping so that systems essential and which do not intrefere
e)      care must be taken that smoke is not pickes up by suctions of hp air compressor and by essentials systems to living spaces
f)       boundaries must be established to ensure that smoke is contained
g)      when using exhaust fans a route top atmosphere must be opened up to allow make up air tyo enter inside

machinery space ventilation:

a)      close the ventilation supply flaps to the machinery space affected
b)      stand by top close ventilation exhaust flaps, but do not close untol ordered, so that the exhaust system can be continue to be used for the first aid fire fighting

c)       restore essentials ventilation:
d)      boundary cooling:
e)      smoke clearance:
f)       area classification:
g)      high fire risk:
h)      explosive risk:
i)        electronic and high value:
j)        accomadation spaces:

courses:

Ø  diploma in occupational health and safety
Ø  diploma in industrial safety
Ø  diploma in electrical safety
Ø  diploma in fire fighting
Ø  diploma in construction safety
Ø  certificate in fire and safety engineering
Ø  diploma in fire and safety engineering
Ø  pg diploma in fire and safety engineering
Ø  certificate in oil  and gas safety
Ø  diploma in oil and gas safety
Ø  diploma in health ,safety and environment
Ø  pg diploma in health ,safety environment

Job Placement

Nsa will give100% job placement assistance to all successful candidates. some of the industries are listed below.

   oil refineries, 
   port trust,
   airport,
   chemical industries,
   insurance,
   construction and
   service industries are main job providers.

students passed out from this institute can find job opportunities as safety supervisor, safety inspector, safety officer, safety manager, fireman and fire officer.


Contact Us:

No. 714, 1st floor, m.t.h road,
mannurpet, chennai – 600 050.
+91 7667442300
ph: 26242038 ,26242318
mobile no:8643055672
website – http://safetyacademy.in/

email : info@safetyacademy.in

Monday, 6 April 2015

FIRE HYDRALICS AND FIRE LOSS CONTROL

FIRE HYDRALICS AND FIRE LOSS CONTROL
LESSON 1  PUMP
INTRODUCTION
PUMP
BASIC REQUIREMENT OF PUMP:

a)      RELIABLE
b)      PORTABLE
c)       SUCTION
d)      SUBJECTING WATER TO PRESSURE
e)      DELIVERY

MAIN PARTS OF PUMP:
a)      GENERATOR PART
b)      SHAFT
c)       PUMP ASSEMBLY

TYPES OF PUMPS:
a)      DISPLACEMENT PUMP
  1. RECIPROCATING PUMP
  2. DIAPHRAGM PUMP’
 THE RECIPROCATING PUMP ARE FURTHUR CLASSIFIED AS:
  1. FORCE PUMP
  2. LIFT PUMP
  3. BUCKET AND PLUNGER PUMP
  4. ROTARY PUMP
B. CENTRIFUGAL PUMP
  1. CONVENTIONAL CENTRIFUGAL PUMP
  2. SELF PRIMING CENTRIFUGAL PUMP
  3. AIR OPERATED PUMP
  • DISPLACEMENT PUMP
  • RECIPROCATING PUMP
  • DIAPHRAGM PUMP
  • CENTRIFUGAL PUMP
  • SELF PRIMING PUMP
  • SUBMERSIBLE PUMP
  • AIR LIFT PUMP
  • VANE TYPE PUMP
BEFORE STARTING PUMP: THE FOLLOWING POINTS ARE TO BE ENSURED BEFORE  STARTING THE PUMP

a)      PUMP IS TO BE KEPT CLOSE TO THE WATER ON STRONG BASE.
b)      CHECK FOR FUEL AND OIL LEVEL IN CASE OF ENGINE DRIVEN AND CORRECT ELECTRIC SUPPLY FOR MOTOR DRIVEN
c)       KINKS AND BENDS IN HOSE ARE TO BE REMOVED
d)      STRAINER SHOUYLD SUBMERGE IN WATER PROPERLY
e)      PRIMING IS TO BE DONE IF REQUIRED
f)       CHECK AND LOOK AT GAUGES
g)      START THE PUMP AND OBSERVE FOR ABNORMAL SOUND IF ANY

REASONS FOR PRIMING FAILURE
a)      DEFECTIVE GLAND PACKING
b)      CHOCKED STRAINER
c)       DEFECT IN PUMP CASING
d)      STRAINER NOT SUBMERGED IN LIQUID
e)      PUMP FILLER OR DRAIN PLUG IS LOOSE
f)       FACULTY JOINTS IN SUCTION LINE

CAVITATION
BOOSTER PUMPS
JOCKEY PUMP
DISCHARGE OF WATER
THE DISCHARGE OF WATER WILL DEPEND ON FOLLOWING FACTORS

a)       PRESSURE OF THE PUMP
b)      FLOW THROUGH PIPE
c)       THE VOLUME OF THE IMPELLER CASING
d)      THE ROTATION AND DESIGN OF THE IMPELLER
e)      BRAKE POWER
f)       SUCTION DEPTH AND DISCHARGE HEIGHT
g)       THE TEMPERATURE AND VISCOSITY OF THE LIQUID
h)      CONDITION OF SUCTION AND DISCHARGE HOSES
i)        CONDITION OF STRAINER

  • SUCTION LIFT
  • DISCHARGE HEIGHTS
LESSON 2 – FLOW OF WATER
INTRODUCTION

ENERGY:  THE LIQUID IS ALWAYS HAVING ENERGY IN IT. THE WATER WILL HAVE FOLLOWING ENERGY

a)      POTENTIALENERGY
b)      PRESSURE ENERGY
c)       KINETIC ENERGY

PARALLEL PIPES

PARALLEL PIPES ARE USED FOR MOVEMENT OF LARGE QUANTITY OF WATER OVER LONG DISTANCE. THIS REDUCVES ENERGY LOSS AND EASY FOR MAINTENANACE

LAWS OF FLUID FRICTIONTHE FLUID IN MOTION IS SUBJECTED TO CERTAIN BASIC
FRICTIONAL LAWS

a)      THE FRICTONAL RESISTANCE IS PROPOTIONAL TO THE VELOCITY.
b)      THE FRICTIONAL RESISTANCE IS INDEPENDENT OF THE PRESSURE.
c)       THE FRICTIONAL RESISTANCE IS PROPOTIONAL TO THE SURFACE AREA.
d)      THE RESISTANCE VARIES WITH TEMPERATURE AND VISCOCITY OF LIQUID.
e)      THE FRICITON IS INDEPENDENT OF THE NATURE (SMOOTHNESS) OF SURFACE.
f)       THE FRICTION IS PROPOTIONAL TO THE DENSITY PF THE LIQUID

CRITICAL VELOCITY
FLOW OF WATER
THE WATER FLOW VARIES IN PIPE DUE TO TYPE OF PUMP , PIPE AND FRICTION . THE TYPES OF PIPE CAN BE CHARACTERISED AS FOLLOWS:

a)      STEADY AND UNSTEADY FLOW
b)      UNIFORM FLOW
c)       LAMINAR FLOW AND TURBULENT FLOW
d)      ROTATIONAL FLOW
e)      COMPRESSIBLE FLOW

COURSES:

Ø  Diploma in occupational Health And Safety
Ø  Diploma in industrial safety
Ø  Diploma in electrical safety
Ø  Diploma in fire fighting
Ø  Diploma in construction safety
Ø  Certificate in fire and safety engineering
Ø  Diploma in fire and safety engineering
Ø  PG diploma in fire and safety engineering
Ø  Certificate in oil  and Gas safety
Ø  Diploma in oil and Gas safety
Ø  Diploma in health ,safety and Environment
Ø  PG diploma in Health ,safety Environment

JOB PLACEMENT

NSA will give100% job placement assistance to all successful candidates. Some of the Industries are listed below.
   Oil Refineries, 
   Port trust,
   Airport,
   Chemical Industries,
   Insurance,
   Construction and
   service industries are main job providers.
Students passed out from this institute can find job opportunities as Safety Supervisor, Safety Inspector, Safety Officer, Safety Manager, Fireman and Fire Officer.

Contact us:

No. 714, 1st Floor, M.T.H Road,
Mannurpet, Chennai – 600 050.
+91 7667442300
Ph: 26242038 ,26242318
Mobile No:8643055672
Website – http://safetyacademy.in/

Email : info@safetyacademy.in


Monday, 16 March 2015

ACCIDENT PREVENTION AND RISK MANAGEMENT LESSON 8

ACCIDENT PREVENTION AND RISK MANAGEMENT
LESSON 8

ACCIDENT INVESTIGATION
INTRODUCTION

ACCIDENT INVESTIGATION:

a)      HOW DID THE ACCIDENT OCCUR?
b)      WHY DID THE ACCIDENT OCCUR?
c)       WHAT CAN BE DONE TO PREVENT RECURRENCES OF SIMILAR ACCIDEN?
d)      WHO WAS RESPONSIBLE FOR ACCIDENT?
a)      WORKER
b)      FOREMAN WHO SUPERVISES AND GUIDES HIM
c)       THE WITNESSES AT THE PLACE OF ACCIDENT
d)      THE MANAGEMENT

INVESTIGATING PERSONNEL:
STEPS OF INVESTIGATION:

a)      ON SPOT PRELIMINARY ENQUIRY IMMEDIATEDLY AFTER ACCIDENTS
b)      CAREFUL AND IMPARTIAL ANALYSIS
c)       PEOPLE WITNESSED THE ACCIDENT ENQUIRED AND THEIR STATEMENT RECORDED.
d)      NOT TO OMIT ANYTHING SAYING THE MAN WAS CARELESS
e)      AVOID LOOKING FOR EXCUSES AND FIND REAL CAUSE
f)       AVOID TRYING TO CONVICT SOME ONE FOR NEGLIGENCE AND REMEMBER THE COMPANY THE SUPERVISOR AND THE WORKER ARE USUALLY AT FAULT TO SOME DEGREE
g)      THOROUGH KNOWLEDGE OF ALL CIRCUMSTANCES SURROUNDINGS AN ACCIDENTS IS GATHERED
h)      A INFORMATION USUALLY INDICATE A DEFINITE NEED FOR MORE INFORMATION EDUCATION AND TRAINING OF THE WORKER AS WELL AS CLOSER FOLLOW UP BY SUPERVISOR AND MANAGEMENT
¨  ACCIDENT REPORTS

¨  CLASSIFICATION OF ACCIDENTS:

a)      FAILURE OF EQUIPTMENTS OR MACHINES
b)      UNSAFE OPERATIONS/UNSAFE ACTS
c)       UNSAFE CONDITIONS OF MACHINE AND PLACE
d)      EMPLOYEE BEHAVIORIST CAUSE
e)      ENVIRONMENT CAUSE
f)       CALAMITY DUE TO NATURAL CAUSES
g)      ELECTRICITY FAULTS AND FAILURES
h)      DUE TO CHEMICALS/EXPLOSION/EXPLOSIVE NATURE
i)        DUE TO ULTEROIR MOTIVES (REMOTE CHANCE)
¨  UNSAFE ACTS

¨  BEHAVIORIST CAUSE:

a)      IMPROPER ATTITUDE DELIBERATE DISOBEDIENCE OF SAFETY RULES CHANCE TAKING DISREGARD OF INSTRUCTION AND ABSENT MINDEDNESS.
b)      LACK OF KNOWLEDGE ANDS SKILL UNDER PREPARED AND ILL TRAINED
c)       PHYSICAL OR MENTAL DEFECT POOR EYE SIGHT POOR HEARING EPILEPSY UNABLE TO HOLD BECAUSE OF WEAKNESS AND AGE FACTOR

¨  ENVIRONMENTAL CAUSE:

a)      IMPROPER GUARDING AND GUARDING REMOVED
b)      DEFECTIVE BROKEN SLIPPERY LOOSE BRAKES DECAYED CORRODED AND CRACKED PART
c)       HAZARDOUS ARRANGEMENT PROCESS PILING STORING LAYOUT OVER LOADING AND MISALIGNING
d)      IMPROPER  ILLUMINATION LESS ILLUMINATION AND GLARING
e)      IMPROPER VENTILATION (POOR DUSTY GASEOUS AND HIGH HUMID)
f)       IMPROPER DRESS CODE (GOGGLES GLOVES SHOES JACKETS HELMETS MASKS AND SLEEVES)

REMEDIAL MEASURES:

a)      DISCOVERING CAUSES OF ACCIDENTS
b)      ANALYSE AVALIABLE RECORDS
c)       INSPECT ALL EQUIPMENT
d)      CHECK PLANS PURCHASE ORDERS AND CONTRACTS FOR SAFETY
e)      PROPER MAINTENANCE INITIATED
f)       STANDARD OPERATING PRQACTICES ENFORCED
g)      PROVIDE GUARDS FOR EXISTING HAZARDS
h)      INSPECTION OF DEFECTS IN EQUIPMENT AND MATERIALS
i)        CORRECTION AND RECTIFICATION OF DEFECTS
j)        FORMULATION OF SAFE PROCEDURES
k)      IMPROVEMENT IN ILLUMINATION AND VENTILATION
l)        PROVIDE SAFETY GADGETS
m)    SPECIFY SPECIAL GADGETS FOR SPECIFIC JOBS
n)      ENTRY RESTRICTIONS ENFORCED
o)      CAPSULE AND REFRESH TRAINING TO PERSONNEL
p)      NEW RECORDS BOOKS AND FILES INTRODUCED
q)      FITNESS LEVEL OF EMPLOYEES ASSESSED
r)       LOOKING AND LEARNING FROM OTHER COMPANIES
s)       COMMUNICATION AND INTERACTION WITH MGMT IMPVD

¨  COURSES:

Ø  Diploma in occupational Health And Safety
Ø  Diploma in industrial safety
Ø  Diploma in electrical safety
Ø  Diploma in fire fighting
Ø  Diploma in construction safety
Ø  Certificate in fire and safety engineering
Ø  Diploma in fire and safety engineering
Ø  PG diploma in fire and safety engineering
Ø  Certificate in oil  and Gas safety
Ø  Diploma in oil and Gas safety
Ø  Diploma in health ,safety and Environment
Ø  PG diploma in Health ,safety Environment

JOB PLACEMENT :

NSA will give100% job placement assistance to all successful candidates. Some of the
Industries are listed below.
        Oil Refineries, 
          Port trust,
   Airport,
   Chemical Industries,
   Insurance,
   Construction and
   service industries are main job providers.
 Students passed out from this institute can find job opportunities as Safety Supervisor, Safety
Inspector, Safety Officer, Safety Manager, Fireman and Fire Officer.

CONTACT US:

No. 714, 1st Floor, M.T.H Road, 
Mannurpet, Chennai – 600 050. 
+91 7667442300 
Ph: 26242038 ,26242318
Mobile No:8643055672
Website – http://safetyacademy.in/
Email : info@safetyacademy.in


Monday, 9 March 2015

ACCIDENT PREVENTION AND RISK MANAGEMENT LESSON 7

ACCIDENT PREVENTION AND RISK MANAGEMENT

LESSON 7 SAFETY INSPECTION
¨  INTRODUCTION

¨  SELECTIVE SAFETY INSPECTION:

a)      TO GET TO THE SPOT DIRECTLY
b)      TO LOOK OBSERVE AND LEARN
c)       TO COPRRECT AS YOU INSPECT
d)      TO REPORT OR MAKE RECORDS CONSTRUCTIVELY

¨  INSPECTION POINTS:

¨  HOUSE KEEPING AND CLEANING
¨  MATERIALS HANDLING METHODS
¨  ADEQUACY OF WORKING SPACE VBETWEEN ARRANGEMENTS OF MACHINES
¨  GUARDING OF ROTATING REVOLVING AND TRANSMISSION MACHINERIES
¨  UPKEEP OF HAND TOOLS
¨  PROPER LOCATIONS OF LADDERS STEPS LIFTS HOISTS AND ELEVATORS
¨  QUALITY OF FLOORS PLATFORMS STAIRS AND RAILING
¨  ELECTRICAL EQUIPMENT AND THEIR OPERATING SWITCHES
¨  LIGTING AND VENTILATION FACILITY
¨  DUSTS FUMES GASES AND VAPOURS
¨  DANGEROUS LIKE ACIDS ANE XPLOSIVES LOCATIONS
¨  ACCESS TO OVERHEAD EQUIPMENT
¨  EXIT ROUTES
¨  LOACTION OF PRESSURE VESSELS AND COPMPRESSORS
¨  LOCATIONS OF FIRE FIGHTINGS  EXTINGUISHERS
¨  SIGN BORADS STICKERS AND OPERATINGS INSTRUCTIONS BOARD
¨  SAFE ELECTRICAL WIRINGS AND CONNECTION
¨  ANY OTHER CONDITIONS THAT LEAD TO HAZARDOUS CONDITIONS

¨  CHEMICALS PLANTS:

a)      SAFETY FROM ACIDS ALKALIS AND OTHER CHEMICALS LEAKS FROM PIPING EQUIPMENT
b)      RELEASE OF TOXIC GASES FUMES VAPOUR AND DUSTS
c)       HAZARDOUS SPLASHES SPILLAGES DURING HANDLING SERVICING MANUFACTURING OPERATION
d)      FIRE AND EXPLOSION HAZARDS
e)      ADEQUATE VENTILLATION BLOWERS EXHAUST DUCTS ABD VENTS
f)       NEED FOR PROTECTIVE ITEMS LIKE GASES MASKS GOGGLES GLOVES RESPIRATORS PROTECTIVE CLOTHING AND SHOES
g)      STORAGE OF CHEMICALS COOL AREAS AND PROTECTED AREAS SELECTION
h)      TRANSFERRING OF LIQUIDS BY SPILL PROOF PUMPS AND METHODS
i)        SPECIAL PRECAUTIONS FOR OXIDISING AND CORROSIVE CHEMICALS
j)        GROUNDINGS OF EQUIPMENT TO PREVENT STATIC ELECTRICITY ACCUMULATION
k)      USE OF COMPRESSED SIR FILLING VENTING AND IN AGITATING CHEMICALS
l)        LOCATIONS OF DRAINS AND STEAM TRAPS
m)    PILING OF DRUMS AND RACKING OF CONTAINERS
n)      STORAGE OPF COMBUSTIBLES SOLIDS AND CHEMICALS
o)      INSTALLATION OF FIRE FIGHTING EQUIPTMENT AND FIRE HYDRANTS
p)      ADEQUATE DISPLAY OF POSTERS SLOGANS WHERE CHEMICALS ARE STORED
q)      STORAGE OF INERT GASES LIKE CO2 AND N2

SAFETY INSPECTION REPORT:

a)      IS THE REPORT WRITTEN PAINLY AND CARRY FACTUAL INFORMATION?
b)      IS IT A CONSTRUCTIVE REPORT?
c)       DOES IT REPRESENT ALL OBSERVATION FAIRLY?
d)      WILL IT HELP TO PREVENT FUTURE ACCIDENT?
e)      IS PERSONNEL INVOLVED IN BRING DOWN THE DEGREE OF DEGREE OF HAZARDS PRASIED AND MERITED?

ADVANTAGES OF PLANT MAINTENANCE:

a)      REDUCED BREAKDOWN S AND DOWNTIME OF MACHINE AND LABOUR
b)      GREATER SAFETY FOR WORKERS
c)       LESS STAND BY OR RESERVE EQUIPMENT
d)      LOW MAINTENANCE AND REPAIRS COMPARED TO BREAK DOWN MAINTENANCE
e)      BETTER PRODUCT QUALTIY AND FEWER REJECTS
f)       INCREASED EQUIPTMENT
g)      BETTER INDUSTRILA MORALE AND INDUSTRRIAL RELATION BECAUSE PRODUCTION WORKERS DO NOT FACE LAY OFF OR LESS INCENTIVE BONUS DUE TO BREAK DOWNS


¨  COURSES:
Ø  Diploma in occupational Health And Safety
Ø  Diploma in industrial safety
Ø  Diploma in electrical safety
Ø  Diploma in fire fighting
Ø  Diploma in construction safety
Ø  Certificate in fire and safety engineering
Ø  Diploma in fire and safety engineering
Ø  PG diploma in fire and safety engineering
Ø  Certificate in oil  and Gas safety
Ø  Diploma in oil and Gas safety
Ø  Diploma in health ,safety and Environment
Ø  PG diploma in Health ,safety Environment


JOB PLACEMENT :

  NSA will give100% job placement assistance to all successful candidates. Some of the Industries are listed below.
     Oil Refineries, 
     Port trust,
   Airport,
   Chemical Industries,
   Insurance,
   Construction and
   service industries are main job providers.
  Students passed out from this institute can find job opportunities as Safety Supervisor, Safety Inspector, Safety Officer, Safety Manager, Fireman and Fire Officer.

CONTACT US:

 No. 714, 1st Floor, M.T.H Road, 
Mannurpet, Chennai – 600 050. 
+91 7667442300 
Ph: 26242038 ,26242318
Mobile No:8643055672
Website – http://safetyacademy.in/
 
Email : info@safetyacademy.in